LibTiePie
0.9.14
Library for interfacing TiePie engineering instruments
|
Functions to control the segment count.
The segment count can be affected by changing the record length.
Functions | |
uint32_t | ScpGetSegmentCountMax (LibTiePieHandle_t hDevice) |
Get the maximum supported number of segments of a specified oscilloscope. More... | |
uint32_t | ScpGetSegmentCount (LibTiePieHandle_t hDevice) |
Get the currently selected number of segments of a specified oscilloscope. More... | |
uint32_t | ScpSetSegmentCount (LibTiePieHandle_t hDevice, uint32_t dwSegmentCount) |
Set the number of segments of a specified oscilloscope. More... | |
uint32_t ScpGetSegmentCountMax | ( | LibTiePieHandle_t | hDevice | ) |
Get the maximum supported number of segments of a specified oscilloscope.
[in] | hDevice | A device handle identifying the oscilloscope. |
0
when unsuccessful. NOT_SUPPORTED | Segment count is not supported by the hardware. |
INVALID_HANDLE | The handle is not a valid oscilloscope handle. |
OBJECT_GONE | The object indicated by the handle is no longer available. |
LIBRARY_NOT_INITIALIZED | The library is not initialized, see LibInit(). |
SUCCESS | The function executed successfully. |
uint32_t ScpGetSegmentCount | ( | LibTiePieHandle_t | hDevice | ) |
Get the currently selected number of segments of a specified oscilloscope.
[in] | hDevice | A device handle identifying the oscilloscope. |
0
when unsuccessful. INVALID_VALUE | The requested value is invalid. |
NOT_SUPPORTED | Segment count is not supported by the hardware. |
INVALID_HANDLE | The handle is not a valid oscilloscope handle. |
OBJECT_GONE | The object indicated by the handle is no longer available. |
LIBRARY_NOT_INITIALIZED | The library is not initialized, see LibInit(). |
SUCCESS | The function executed successfully. |
uint32_t ScpSetSegmentCount | ( | LibTiePieHandle_t | hDevice, |
uint32_t | dwSegmentCount | ||
) |
Set the number of segments of a specified oscilloscope.
[in] | hDevice | A device handle identifying the oscilloscope. |
[in] | dwSegmentCount | The required number of segments. |
0
when unsuccessful. VALUE_CLIPPED | The requested segment count is outside the valid range and clipped to the closest limit. |
VALUE_MODIFIED | The requested segment count is within the valid range but not available. The closest valid value is set. |
INVALID_VALUE | The requested value is invalid. |
NOT_SUPPORTED | Segment count is not supported by the hardware. |
INVALID_HANDLE | The handle is not a valid oscilloscope handle. |
OBJECT_GONE | The object indicated by the handle is no longer available. |
LIBRARY_NOT_INITIALIZED | The library is not initialized, see LibInit(). |
SUCCESS | The function executed successfully. |